UFI Model 1089 Family of Checktrodes™

Physiological recordings can be easily contaminated by noise and interference; in most cases, high electrode contact impedance is a big part of the problem. Noise often appears as 50 or 60 Hz "hum" from surrounding AC-powered electrical devices or as erratic spikes due to any motion of the lead wires. In virtually every case, these troublesome artifacts can be mitigated or completely eliminated by reducing contact impedance at the skin/electrode interface. UFI's Checktrode™ electrode testers are designed to help accomplish this task.

UFI offers four time- and frustration-saving electrode contact impedance checking instruments. Our standard 1089 allows rapid evaluation of contact impedance when two electrodes are used. For multiple electrode configurations, our 1089ES and 1089NP allow rapid, individual evaluation of large electrode arrays, such as EEG caps. The 1089e is our latest offering -- and at an economical price too!


Model 1089 MkIII Checktrode

The UFI model 1089 MkIII Checktrode supplies quick and easy evaluation of total contact impedance and offset voltage between two applied electrodes. The 1089 uses an AC excitation method which removes the effects of the polarization errors from the impedance reading. Leads with both the older .080" pin plugs as well as the newer .060" sheathed safety jacks are supported. The inclusion of a standard male snap allows electrode lead testing as well. A loaded battery test function is also provided. The 1089 is powered by a standard 9V battery, and automatically shuts down after 5 minutes.



Review a representative Model 1089 MkIII user manual


Model 1089ES Checktrode with Lead Selector

The "ES" includes a switch and associated circuitry to select up to 22 separate electrode leads. This allows the 1089ES to be used to check applied electrode contact impedance of multiple electrode configurations such as Cranial EEG "caps" -- rapidly and painlessly. Price includes interfacing to the connector of your choice for most connectors. Contact UFI for more details.



Review a representative Model 1089ES user manual


Model 1089NP Checktrode with Lead Selector

The Model 1089NP evolved from the 1089ES, and has a few important differences. Whereas the 1089ES is a general-purpose instrument, the Model 1089NP is intended for use with several specific electrode caps. These include the Brainmaster Discovery qEEG system cap, the NeuroPulse Systems qEEG cap, the Mistar Systems cap and any standard Electro Cap or Comby Cap used with other qEEG systems.

For ease of use, Model 1089NP rotary selection switch positions are directly keyed to electrode site names for the listed caps. A two-position TEST switch permits the two reference electrodes supplied with these caps to be tested against each other. When good contact between them has been established, just flip the TEST switch to link the two reference electrodes, then check contact impedances of the remaining cap electrodes.



Review a representative Model 1089NP user manual


1089 general specifications


Model 1089e Economy Checktrode

Built on years of 1089 Checktrode service, this new design incorporates a microprocessor. A crystal-controlled 30 Hz sine wave is supplied to the electrode pair under test. Leads connect to the electrodes using the industry standard 0.060" safety jacks. The 1089e supplies a simple pass-fail LED indication for the contact impedance ranges of <5KOhm, <10 KOhm, <20 KOhm, <50 KOhm, and >50 KOhm. Simple, single-switch operation, with automatic power-down, further simplifies the use of this essential, 9V battery-powered instrument.




Model 1089e specifications


Review a representative Model 1089e user manual



Published references to the Checktrode